C&I ESS
C&I ENERGY STORAGE SYSTEM
CNTE’s commercial and industrial energy storage solutions use CATL LFP battery cells and intelligent liquid cooling systems, offering solutions from 206 kWh to 4 MWh.
Home >
Product Advantage
Specifications
- STAR T
- STAR H
- Ener Mini
STAR T-285
Standardized Design,Up to 4MWh Max Capacity,20 ft Standard Container,Smart Liquid Cooling
Learn More
Product Model | STAR T-285 |
Battery Specifications | |
Battery Type | LFP |
Battery Model | 285Ah |
Energy Capacity | 1896~3793kWh |
Voltage Range | 1164.8~1497.6Vdc |
P-rate | 1P |
Cooling Method | Liquid Cooling |
Ingress Protection | IP55 |
System Dimensions (W×D×H) | 6058 ×2438×2896 mm |
Weight | ≈35T |
Compliance | UN 38.3, UN 3536, UL 1973, UL 9540A, IEC 62619, IEC 61000-6-2/-4, IEC 62477-1, IEC 62933-5-2, IEC 63056, IEC 60730-1 |
PCS Specifications | |
Rated AC Power | 1000kW~1725kW |
Rated Grid Voltage | 400~690Vac |
Total Harmonic Distortion | <3% |
Rated Grid Frequency | 50/60Hz |
Peak Efficiency | 0.98 |
Power Factor | -1 to 1, continuously adjustable |
Ingress Protection | IP54 |
System Dimensions (W×D×H) | 2200×1100×2280 mm |
Weight | ≈2.6T |
Compliance | EN50549, G99, VDE AR-N 4110, NTS Spain, IEC 62477, IEC 61000-6-2, IEC 61000-6-4, UL 1741, IEEE1547:2018, UL1741 SB |
General Specifications | |
Operating Temperature Range | -25~55 °C (>45℃ derating) |
Relative Humidity Range | 0~95% (No Condensation) |
Max. Working Altitude | 4000m (>2000m derating) |
Fire Safety Equipment | Heat detectors, Aerosol, Smoke detectors, Flammable gas detector, Exhausting system, Dry pipe (optional) |
STAR T-306
Standardized Design,Up to 4MWh Max Capacity,20 ft Standard Container,Smart Liquid Cooling
Learn More
Product Model | STAR T-306 |
Battery Specifications | |
Battery Type | LFP |
Battery Model | 306Ah |
Energy Capacity | 2036~4073kWh |
Voltage Range | 1164.8~1497.6Vdc |
P-rate | 0.5P |
Cooling Method | Liquid Cooling |
Ingress Protection | IP55 |
System Dimensions (W×D×H) | 6058 ×2438×2896 mm |
Weight | ≈35T |
Compliance | UN 38.3, UN 3536, UL 1973, UL 9540A, IEC 62619, IEC 61000-6-2/-4, IEC 62477-1, IEC 62933-5-2, IEC 63056, IEC 60730-1 |
PCS Specifications | |
Rated AC Power | 1000kW~1725kW |
Rated Grid Voltage | 400~690Vac |
Total Harmonic Distortion | <3% |
Rated Grid Frequency | 50/60Hz |
Peak Efficiency | 0.98 |
Power Factor | -1 to 1, continuously adjustable |
Ingress Protection | IP54 |
System Dimensions (W×D×H) | 2200×1100×2280 mm |
Weight | ≈2.6T |
Compliance | EN50549, G99, VDE AR-N 4110, NTS Spain, IEC 62477, IEC 61000-6-2, IEC 61000-6-4, UL 1741, IEEE1547:2018, UL1741 SB |
General Specifications | |
Operating Temperature Range | -25~55 °C (>45℃ derating) |
Relative Humidity Range | 0~95% (No Condensation) |
Max. Working Altitude | 4000m (>2000m derating) |
Fire Safety Equipment | Heat detectors, Aerosol, Smoke detectors, Flammable gas detector, Exhausting system, Dry pipe (optional) |
Product Model | STAR H-232 |
Battery Specifications | |
Battery Type | LFP |
Battery Model | 280Ah |
Energy Capacity | 232kWh |
Voltage Range | 728~936VDC |
P-rate | 0.5P |
Compliance | UN 38.3, UN 3480, UL 1973, UL 9540A, UL9540, IEC 62619, IEC 61000-6-2/-4, IEC 62477-1, IEC 60356, IEC 60730-1 |
PCS Specifications | |
Rated AC Power | 100kW |
Rated Grid Voltage | 400/480Vac |
Total Harmonic Distortion | <3% |
Rated Grid Frequency | 50/60Hz |
Peak Efficiency | 98% |
Power Factor | -1 to 1, continuously adjustable |
Compliance | EN 50549, G99, VDE AR-N 4105, NTS Spain, IEC 62477, IEC 61000-6-2, IEC 61000-6-4, UL 1741, IEEE1547:2018, UL1741 SB |
General Specifications | |
Cooling Method | Liquid Cooling |
Operating Temperature Range | -25~55 °C (>45℃ derating) |
Relative Humidity Range | 0~95% (No Condensation) |
Max. Working Altitude | 4000m (>2000m derating) |
Fire Safety Equipment | Aerosol, Smoke detector, Heat detector, Flammable gas detector (optional), Deflagration vent (optional), Dry pipe (optional) |
Battery Compartment Ingress Protection | IP65 |
System Dimensions (W×D×H) | ≈1500×1300×2000 mm |
Weight | ≈3.5T |
Isolation Transformer | Off-Grid Require |
*If there are any changes in product size and parameters, please refer to the latest information. |
Product Model | STAR H-237 |
Battery Specifications | |
Battery Type | LFP |
Battery Model | 285Ah |
Energy Capacity | 237kWh |
Voltage Range | 728~936VDC |
P-rate | 1P |
Compliance | UN 38.3, UN 3480, UL 1973, UL 9540A, UL9540, IEC 62619, IEC 61000-6-2/-4, IEC 62477-1, IEC 60356, IEC 60730-1 |
PCS Specifications | |
Rated AC Power | 125kW×2 (derating to 237kW) |
Rated Grid Voltage | 400/480Vac |
Total Harmonic Distortion | <3% |
Rated Grid Frequency | 50/60Hz |
Peak Efficiency | 98% |
Power Factor | -1 to 1, continuously adjustable |
Compliance | EN 50549, G99, VDE AR-N 4105, NTS Spain, IEC 62477, IEC 61000-6-2, IEC 61000-6-4, UL 1741, IEEE1547:2018, UL1741 SB |
General Specifications | |
Cooling Method | Liquid Cooling |
Operating Temperature Range | -25~55 °C (>45℃ derating) |
Relative Humidity Range | 0~95% (No Condensation) |
Max. Working Altitude | 4000m (>2000m derating) |
Fire Safety Equipment | Aerosol, Smoke detector, Heat detector, Flammable gas detector (optional), Deflagration vent (optional), Dry pipe (optional) |
Battery Compartment Ingress Protection | IP65 |
System Dimensions (W×D×H) | ≈1500×1300×2000 mm |
Weight | ≈3.5T |
Isolation Transformer | No Require |
*If there are any changes in product size and parameters, please refer to the latest information. |
Product Model | STAR H-254 SP |
Battery Specifications | |
Battery Type | LFP |
Battery Model | 306Ah |
Energy Capacity | 254kWh |
Voltage Range | 728~936VDC |
P-rate | 0.5P |
Compliance | UN 38.3, UN 3480, UL 1973, UL 9540A, UL9540, IEC 62619, IEC 61000-6-2/-4, IEC 62477-1, IEC 60356, IEC 60730-1 |
PCS Specifications | |
Rated AC Power | 125kW |
Rated Grid Voltage | 400/480Vac |
Total Harmonic Distortion | <3% |
Rated Grid Frequency | 50/60Hz |
Peak Efficiency | 98% |
Power Factor | -1 to 1, continuously adjustable |
Compliance | EN 50549, G99, VDE AR-N 4105, NTS Spain, IEC 62477, IEC 61000-6-2, IEC 61000-6-4, UL 1741, IEEE1547:2018, UL1741 SB |
General Specifications | |
Cooling Method | Liquid Cooling |
Operating Temperature Range | -25~55 °C (>45℃ derating) |
Relative Humidity Range | 0~95% (No Condensation) |
Max. Working Altitude | 4000m (>2000m derating) |
Fire Safety Equipment | Aerosol, Smoke detector, Heat detector, Flammable gas detector (optional), Deflagration vent (optional), Dry pipe (optional) |
Battery Compartment Ingress Protection | IP65 |
System Dimensions (W×D×H) | ≈1500×1300×2000 mm |
Weight | ≈3.5T |
Isolation Transformer | No Require |
*If there are any changes in product size and parameters, please refer to the latest information. |
Product Model | Ener Mini |
Battery Specifications | |
Battery Type | LFP |
Battery Model | 280Ah |
Energy Capacity | 206kWh |
Voltage Range | 646.8~831.6Vdc |
P-rate | 1P |
Cooling Method | Liquid cooling |
Battery Compartment Ingress Protection | IP55 |
System Dimensions (W×D×H) | 1270×1500×2280 mm |
Weight | ≈2.5T |
Compliance | UN 38.3, UN 3480, UL 1973, UL 9540A, IEC 62619, IEC 61000-6-2/-4, IEC 62477-1, IEC 63056, IEC 60730-1 |
PCS Specifications | |
Rated AC Power | 100/500/1000kW |
Rated Grid Voltage | 400Vac |
Max. AC Current | 167/760/1672A |
Total Harmonic Distortion | <3% |
Rated Grid Frequency | 50/60Hz |
Peak Efficiency | 98% |
Power Factor | -1 to 1, continuously adjustable |
Ingress Protection | IP54 |
System Dimensions (W×D×H) | 810×275×845 mm for 100kW 1500×1150×2450 mm for 500kW 2200×1100×2280 mm for 1000kW |
Weight | 98kg for 100kW 600kg for 500kW 2.6T for 1000kW |
Compliance | EN50549, G99, VDE AR-N 4105, VDE AR-N 4110, NTS Spain, IEC 62477, IEC 61000-6-2, IEC 61000-6-4, UL 1741, IEEE1547:2018, UL1741 SB |
General Specifications | |
Operating Temperature Range | -25~55 °C (>45℃ derating) |
Relative Humidity Range | 0~95% (No Condensation) |
Max. Working Altitude | 4000m (>2000m derating) |
Fire Safety Equipment | Aerosol or NVAC1230, Smoke detector, Heat detectors |
Supporting Products
Application Scenario
View All