Utility-Scale ESS
Lorem ipsum dolor sit amet, inciderint referrentur te vim.
The Utility-scale ESS consists of photovoltaic modules, energy storage battery systems, bi-directional converters, grid-connected inverters, box-type substations and other equipment,and is better at smoothing power output and energy consumption.
Home >
Product Advantages
Fast Grid Connection
Support access to 380V, 10kV and 35kV power grids
High Conversion Rate
Liquid cooling temperature control, improving energy conversion efficiency
Fast Construction
Modular design, flexible deployment, shortened construction period
Customization
Flexible configuration of system parameters, providing complete power solutions
Application Scenario
Grid Side
Power Generation Side
Supporting Products
ESS Container
EMS/Cloud Platform
-
Utility-Scale (Above 10MWh)
Max. Number of Systems in Parallel | 2 | |||
PCS Specifications | 1000kW | 1200kW | 1500kW | 1725kW |
Rated AC Power | 1000 kVA / kW | 1200 kVA / kW | 1500 kVA / kW | 1725 kVA / kW |
Rated Grid Voltage | 400 Vac | 480 Vac | 600 Vac | 690 Vac |
Max. AC Current | 1672A | 1448A | ||
Total Harmonic Distortion | <3% | |||
Rated Grid Frequency (Range) | 50 Hz / 60 Hz | |||
Peak Efficiency | 98% | |||
Power Factory | -1 to 1, continuously adjustable | |||
ENERGY STORAGE | ||||
Rated Energy DC | 3727.36kWh | |||
Voltage Range (Nominal Voltage) | 1164.8 ~ 1497.6Vdc ( 1331.2Vdc ) | |||
Chemistry | LFP | |||
DIMENSIONS & WEIGHTS | ||||
System Dimensions (mm, W x D x H) | 2200 x 1100 x 2280 for PCS, 2462 x 6058 x 2896 for each Battery Container |
|||
Weight of Key Components (kg) | 2600 kg for PCS, 35000 kg per 3727.36 kWh Battery Container |
ENVIRONMENTAL | |
Operating Temperature Range / Humidity Range | -20~50 °C (PCS derating at 45 to 55 °C) / 0 to 95% RH non-condensing |
Altitudes | <4000m (derating >2000m) |
IP Ratings | Battery System IP55, PCS IP54, Control cabinet IP54 |
FEATURES | |
Battery Monitoring System | YES ‒ Capable through CNTE monitoring system |
Fire Suppression System | Pre-integrated Fire Suppression system with smoke and heat detectors plus aerosols |
COMPLIANCE | |
PCS Related Standards | VDE AR-N 4110, G99, IEC 62477, IEC 61000-6-2, IEC 61000-6-4 IEEE1547:2018, UL 1741, UL1741 SB |
Battery Related Standards | UN 38.3, UN3536, IEC 62619, IEC 62933-5-2, IEC 63056, IEC 62477-1, UL 1973, UL9540A |
-
Utility-Scale (Above 10MWh)
Max. Number of Systems in Parallel | 2 | |||
PCS Specifications | 1000kW | 1200kW | 1500kW | 1725kW |
Rated AC Power | 1000 kVA / kW | 1200 kVA / kW | 1500 kVA / kW | 1725 kVA / kW |
Rated Grid Voltage | 400 Vac | 480 Vac | 600 Vac | 690 Vac |
Max. AC Current | 1672A | 1448A | ||
Total Harmonic Distortion | <3% | |||
Rated Grid Frequency (Range) | 50 Hz / 60 Hz | |||
Peak Efficiency | 98% | |||
Power Factory | -1 to 1, continuously adjustable | |||
ENERGY STORAGE | ||||
Rated Energy DC | 3727.36kWh | |||
Voltage Range (Nominal Voltage) | 1164.8 ~ 1497.6Vdc ( 1331.2Vdc ) | |||
Chemistry | LFP | |||
DIMENSIONS & WEIGHTS | ||||
System Dimensions (mm, W x D x H) | 2200 x 1100 x 2280 for PCS, 2462 x 6058 x 2896 for each Battery Container |
|||
Weight of Key Components (kg) | 2600 kg for PCS, 35000 kg per 3727.36 kWh Battery Container |
ENVIRONMENTAL | |
Operating Temperature Range / Humidity Range | -20~50 °C (PCS derating at 45 to 55 °C) / 0 to 95% RH non-condensing |
Altitudes | <4000m (derating >2000m) |
IP Ratings | Battery System IP55, PCS IP54, Control cabinet IP54 |
FEATURES | |
Battery Monitoring System | YES ‒ Capable through CNTE monitoring system |
Fire Suppression System | Pre-integrated Fire Suppression system with smoke and heat detectors plus aerosols |
COMPLIANCE | |
PCS Related Standards | VDE AR-N 4110, G99, IEC 62477, IEC 61000-6-2, IEC 61000-6-4 IEEE1547:2018, UL 1741, UL1741 SB |
Battery Related Standards | UN 38.3, UN3536, IEC 62619, IEC 62933-5-2, IEC 63056, IEC 62477-1, UL 1973, UL9540A |
-
Utility-Scale (Above 10MWh)
Max. Number of Systems in Parallel | 2 | ||
PCS Specifications | 1200kW | 1500kW | 1725kW |
Rated AC Power | 1200 kVA / kW | 1500 kVA / kW | 1725 kVA / kW |
Rated Grid Voltage | 480 Vac | 600 Vac | 690 Vac |
Max. AC Current | 1604A | ||
Total Harmonic Distortion | <3% | ||
Rated Grid Frequency (Range) | 50 Hz / 60 Hz | ||
Peak Efficiency | 98% | ||
Power Factory | Four quadrants | ||
ENERGY STORAGE | |||
Rated Energy DC | 3727.36kWh | ||
Voltage Range (Nominal Voltage) | 1164.8 ~ 1497.6Vdc ( 1331.2Vdc ) | ||
Chemistry | LFP | ||
DIMENSIONS & WEIGHTS | |||
System Dimensions (mm, W x D x H) | 2200 x 1100 x 2260 for PCS, 2462 x 6058 x 2896 for each Battery Container |
||
Weight of Key Components (kg) | 2600 kg for PCS, 3700kg per 3727.36 kWh Battery Container |
ENVIRONMENTAL | |
Operating Temperature Range / Humidity Range | -20~50 °C (PCS derating at 45 to 55 °C) / 0 to 95% RH non-condensing |
Altitudes | <4000m (derating >2000m) |
IP Ratings | Battery System IP55, PCS IP54, Control and DC Combiner Cabinet IP54 |
FEATURES | |
Battery Monitoring System | YES ‒ Capable through CNTE monitoring system |
Fire Suppression System | Pre-integrated Fire Suppression system with smoke and heat detectors plus aerosols |
COMPLIANCE | |
PCS Related Standards | IEEE 1547:2018, UL 1741, UL 1741 SB |
Battery Related Standards | UN 38.3, UN 3536, UL 1973, UL 9540A |